Contact Us

Home > Products

arabian dyn11 copper aluminum winding cooling fans

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • China 22kv 125kVA Onan Dyn11 3 Phase Distribution ...

    We always provide customers with 22kv 125kVA Onan Dyn11 3 Phase Distribution Electrical Power Transformer with full enthusiasm, sincere cooperation attitude, and win-win business philosophy. Our company not only provides a perfect network sales system, but also a perfect after-sales system, so that customers can buy at ease, use at ease and ...

    Get Price
  • Transformer Design & Design Parameters

    2014-12-8 · Auxiliary losses are generated by cooling equipment: •fans, •pumps. Typically, these losses are not significant when compared to no-load and load losses. The auxiliary losses depend on the cooling stage of the unit, reaching maximum for top power rating. Transformer Consulting Services Inc. Transformer Design: Loss Evaluation Auxiliary losses

    Get Price
  • Air Cooler Cooling Fan Electric Motor Customized ...

    2021-8-28 · Buy Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Speed at Power Cool AC Parts Trading L.L.C in Dubai. ... I have a question about Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Speed. Get Quotation. SKU: YDK160-245-4A2-1-1-1-1 Categories: ... 5 HP Fan Motor Copper Winding For Air Condition.

    Get Price
  • Buy cooling fan motor, Good quality cooling fan motor ...

    SYZ9-9-1400 HVAC centrifugal air conditioning blower fan with double air flow inlet, metal centrifugal fan 3250m3/h. SYZ10-10 1400RPM Centrifugal Duct Fan with Single Phase Capacitor Motor Model YDK550-4 air volume 4250m3/h. EC Fan Motor. Indoor Central Air Conditioner EC Fan Motor variable Speed 30 Watt - …

    Get Price
  • High Reliability Maintenance-free Environmentally Friendly

    2021-8-28 · HV windings are made of copper electromagnetic wire and insulated with fiberglass mats through segmented cylindrical structure, and thus with a low voltage between layers and strong over-voltage resistance. The winding of larger capacity has a heat-radiating air passage to make a good heat radiation. Eaton also produces LV copper-foil windings.

    Get Price
  • 240V 850RPM 50Hz 6 Pole Universal HVAC Fan Motor with

    High quality 240V 850RPM 50Hz 6 Pole Universal HVAC Fan Motor with 100% Copper Winding from China, China's leading ceiling fan dc motor product, with strict quality control hvac fan motor factories, producing high quality hvac fan motor products.

    Get Price
  • Our OEM factory is a certified company for its Quality ...

    2020-4-18 · • Process : Winding into mold, where resin added • Oven curing process (once encapsulated) SECONDARY WINDING (L.V.) • Copper or Aluminum • Beginning and end of winding: welded plates for connections COOLING FANS • Installed under the HV and LV windings into the interspaced HV-LV • Different sizes, according to rated power 25% overload.

    Get Price
  • URBAN KING ® alastar Heavy Duty Metal Fresh Air Exaust

    A & Y Heavy Duty Metal Fresh Air Exhaust Fan for Kitchen/Bathroom (Blade Size225 MM/9 Inches), Black -Copper Winding 3.2 out of 5 stars 19 2 offers from ₹999.00

    Get Price
  • Fan In Roorkee, Fan Dealers & Traders In Roorkee,

    Browse listings of fan dealers in Roorkee, Uttarakhand with traders, distributors, wholesalers, manufacturers & suppliers. Get best fan price in Roorkee offered by verified companies.

    Get Price
  • fan cooling for transformer, fan cooling for transformer ...

    Alibaba.com offers 3,591 fan cooling for transformer products. A wide variety of fan cooling for transformer options are available to you, such as installation, applicable industries, and certification.

    Get Price
  • Arab Tech Group

    The windings are generally made up of copper. However, Aluminum windings can also be offered. All the standard designs have been proven by type testing including impulse, temperature rise, sound level and short circuit tests. Utes's substation …

    Get Price
  • Datsons Electronics Pvt. Ltd.

    2021-7-16 · Delta-Star (Dyn11), Delta-ZigZag Star (Dyn11) K-Rating: K13,K20 Prefered : Electrostatic Shielding : Copper/Brass - Foil/Mesh Between The winding : Temperature Monitoring: Temp meter: Outgoing: Isolator MCCB /ACB/HRC FUSE : Input-output Status/Indication : ON/OFF/TRIP Solid State Indication, PFC As Requied: Distribution Details : MCBs D ...

    Get Price
  • Arab Tech Group

    The windings are generally made up of copper. However, Aluminum windings can also be offered. All the standard designs have been proven by type testing, including Impulse withstand, temperature rise, sound level and short circuit tests. Utec's pad-mounted distribution transformers share the following features: Safe, reliable and easy for ...

    Get Price
  • Air Cooler Cooling Fan Electric Motor Customized ...

    2021-8-28 · Buy Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Speed at Power Cool AC Parts Trading L.L.C in Dubai. ... I have a question about Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Speed. Get Quotation. SKU: YDK160-245-4A2-1-1-1-1 Categories: ... 5 HP Fan Motor Copper Winding For Air Condition.

    Get Price
  • Transgear/Products

    2017-9-16 · Vector Group Dyn11. Continuous Duty. Copper Aluminum Wound HV Side cable Box LV Side Cable Box Bus Duct ... Winding Temperature scanner with alarm and trip contacts Remote tap changer control cubicle for OLTC transformer. Neutral Current Transformer Blowers and Exhaust Fans for Forced Cooling and enhanced capacity for transformer Surge ...

    Get Price
  • 240V 850RPM 50Hz 6 Pole Universal HVAC Fan Motor with

    High quality 240V 850RPM 50Hz 6 Pole Universal HVAC Fan Motor with 100% Copper Winding from China, China's leading ceiling fan dc motor product, with strict quality control hvac fan motor factories, producing high quality hvac fan motor products.

    Get Price
  • Buy cooling fan motor, Good quality cooling fan motor ...

    SYZ9-9-1400 HVAC centrifugal air conditioning blower fan with double air flow inlet, metal centrifugal fan 3250m3/h. SYZ10-10 1400RPM Centrifugal Duct Fan with Single Phase Capacitor Motor Model YDK550-4 air volume 4250m3/h. EC Fan Motor. Indoor Central Air Conditioner EC Fan Motor variable Speed 30 Watt - 120 Watt

    Get Price
  • Fan In Jalandhar, Fan Dealers & Traders In Jalandhar, Punjab

    Browse listings of fan dealers in Jalandhar, Punjab with traders, distributors, wholesalers, manufacturers & suppliers. Get best fan price in Jalandhar offered by verified companies.

    Get Price
  • 51-SDMS-03 SPECIFICATIONS FOR DISTRIBUTION

    2018-8-15 · either 50 mm² copper or 70 mm² aluminum with heat/cold/pre-mold termination. The box shall have single-gasket, removable, bolted cover. Its bottom plate shall be in two halves with cable entry steel knockouts suitable for the aforementioned cables. Loose rubber bushings shall be provided inside of this box for the knockouts.

    Get Price
  • DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

    2014-3-19 · winding temperatures to be monitored. This shall consist of two sensors placed on each low-voltage winding, i.e. three alarm sensors and three trip out sensors. An indicator shall be installed on the front door of the bay to indicate continuously the winding temperature. This shall be installed on the middle low voltage winding.

    Get Price
  • Three Phase Transfarmer - Three Phase Transformer ...

    Dyn11. Winding Material. Copper Aluminium. Primary Voltage. 11, 22, 33 KV. Secondary Voltage. 433/415/400 V or as per customer specifications and requirement. Duty, type. Continuous duty Outdoor/Indoor, Conventional or hermetically sealed. Mounting. Pole or Ground Mounted. No. Of Phases. 3 Phase. Class of insulation. Class A. Frequency. 50 Hz ...

    Get Price
  • Transgear/Products

    2017-9-16 · Dry Type Cast Resin and Vacuum Impregnated distribution transformer 3 phase, 50 Hz, 11kV/0.433V Range: 25KVA to 2500KVA, Voltage class: Up to 33KV Off Load Tap Links Changer to provide +5% to -5% taps in steps of 2.5% On Load Air Vacuum Type Tap Changer to provide +5% to -15% taps in steps of 2.5% Class F/H insulated. Vector Group Dyn11. Continuous Duty.

    Get Price
  • Cast Resin Transformers - Fuji Electric

    2018-1-10 · Copper : Aluminum 100 : 61 1 : 1.64 8.9 : 2.7 3.3 : 1 100 : 50 Material Aluminum Copper Epoxy resin Thermal expansion coefficient [mm/mm.h.℃] 2.3 x 10-5 1.6 x 10-5 3.3 x 10-5 Copper > Aluminum Thermal stress acting Aluminum sheet winding Thermal stress acting on winding Potential distribution Cylindrical winding Sheet winding Transformer ...

    Get Price
  • Air Cooler Cooling Fan Electric Motor Customized ...

    2021-8-28 · Buy Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Speed at Power Cool AC Parts Trading L.L.C in Dubai. ... I have a question about Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Speed. Get Quotation. SKU: YDK160-245-4A2-1-1-1-1 Categories: ... 5 HP Fan Motor Copper Winding For Air Condition.

    Get Price
  • Amazon.in: ₹500 - ₹1,000 - Exhaust Fans Fans: Home & Kitchen

    URBAN KING ® alastar Heavy Duty Metal Fresh Air Exaust Fan for Kitchen/Bathroom (Copper Winding, 12INCH/300MM) 3.6 out of 5 stars 292 ₹989 ₹ 989 ₹1,599 ₹1,599 Save ₹610 (38%)

    Get Price
  • ITEE Journal ISSN: - 2306-708X

    2014-4-8 · 3. Cross-over winding: This winding is done mainly in small distribution transformer. Here copper wire is used as a coil which is wound one after another across the core. 4. Foil winding: This is almost same as cross-over winding. But here aluminum foil is used across the core rather than the copper wire.

    Get Price
  • AET-DTKF-2004-01 - AET Dry Type K Factor Power

    2020-9-2 · Copper Strips with Class H (220 oC) enameled coated. Class H(NOMEX) Insulation material is used between overlapping turns or layers. Axial channels are used between layers of primary and secondary winding to provide air gap for uniform cooling. High temperature tolerant fiberglass boards are used as bobbins to separate the core and windings.

    Get Price
  • 51-SDMS-03 SPECIFICATIONS FOR DISTRIBUTION

    2018-8-15 · either 50 mm² copper or 70 mm² aluminum with heat/cold/pre-mold termination. The box shall have single-gasket, removable, bolted cover. Its bottom plate shall be in two halves with cable entry steel knockouts suitable for the aforementioned cables. Loose rubber bushings shall be provided inside of this box for the knockouts.

    Get Price
  • Eaton Pad-mounted Transformer

    2021-9-8 · laser-scribed anodized aluminum Removable cabinet walls Drip shield Type Three Phase, 50 or 60 Hz, 65 ºC Rise (55 ºC, 55/65 ºC), 65/75 °C, 75 °C Fluid Type Mineral oil or Envirotemp™ FR3™ fluid Coil Configuration 2-winding or 4-winding or 3-winding (Low-High-Low), 3-winding (Low-Low-High) Size 45 – 10,000 kVA Primary Voltage 2,400 ...

    Get Price
  • Two Winding Transformer-China Two Winding Transformer ...

    Pad Mounted Transformer 1500kVA 13200V/400/230VAC Aluminum/Copper Winding. Coupons Available. US $ 9,370-15,000 Piece FOB. MOQ: 1 Piece. Cooling Method : Oil-immersed Type Transformer. Since 2010. Contact Supplier. Pearl Electric Co., Ltd. …

    Get Price
  • Arab Tech Group

    The windings are generally made up of copper. However, Aluminum windings can also be offered. All the standard designs have been proven by type testing including impulse, temperature rise, sound level and short circuit tests. Utes's substation …

    Get Price
  • Three Phase Transfarmer - Three Phase Transformer ...

    Dyn11. Winding Material. Copper Aluminium. Primary Voltage. 11, 22, 33 KV. Secondary Voltage. 433/415/400 V or as per customer specifications and requirement. Duty, type. Continuous duty Outdoor/Indoor, Conventional or hermetically sealed. Mounting. Pole or Ground Mounted. No. Of Phases. 3 Phase. Class of insulation. Class A. Frequency. 50 Hz ...

    Get Price
  • 51-SDMS-04 SPECIFICATIONS FOR DISTRIBUTION

    2016-5-30 · mm² copper or 70 mm² aluminum with heat/cold/pre-mold termination. The box shall have single-gasket, removable, bolted cover. Its bottom plate shall be in two halves with cable entry steel knockouts suitable for the aforementioned cables. Loose rubber bushings shall be provided inside of this box for the knockouts.

    Get Price
  • SCB-800kVA 10kV Dry Type Transformer

    2021-8-18 · Cooling mode: AN/AF: Winding material (HV) Copper/Copper: Optional Windings : Aluminum/Aluminum: Degree of protection: IP00: HV tapping +/-2*2.5%: Insulation material : Cast resin (HV) Pre-impregnated (LV) Insulation level: Primary: 28kV AC Secondary: 3kV AC: BIL: 75kV for primary circuit: Type of installation: Indoor: Maximum attitude <1000m ...

    Get Price
  • Classes 7200, 7300, 7400 - Steven Engineering

    2004-10-26 · 225–10,000 kVA (fan cooling allows ... Basic impulse level of the primary winding shall be [_____kV] [as specified in ANSI C57.12.00 for comparable kV class]. G. The transformer shall be of sealed-tank construction or sufficient strength to withstand ... H. Coils shall be wound with [copper] [aluminum] conductors. I. Core and coil assembly ...

    Get Price
  • Medium voltage products Technical guide The MV/LV ...

    2018-7-15 · controlgear - Part 210: Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV – CEI 99-4: Customer/End user guide to creating MV/LV electrical substations – CEI EN 61936-1: CEI classification: 99-2, Power

    Get Price
  • Cast Resin Transformers

    OTDS manufactures 3 phase cast resin transformers up to 15mva and dry type up to 150kva. Our voltage range is up to 36kv for cast resin units and 3kV on dry type transformers. Our three-phase transformers of cast resin type, class F insulation system with natural (AN) cooling are designed for indoor installation.

    Get Price
  • 3 Speed Evaporative Cooler Motor 450V 10μF Capacitor ...

    2021-9-10 · Winding: 100% pure copper. Product features: 1. Single phase motor with steel housing, designed for cooling system, evaporative cooler etc, suit for hot weather environments. ... 375W 1/2 HP Air Cooler Motor Electric AC Air Conditioning System. Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Spe...

    Get Price
  • english - EL.PI. CAST-RESIN

    2013-9-18 · LV windings are made with an aluminum conductor strip featuring the same height as the winding and a class F insulation strip, then they are vacuum impregnated in epoxy resin and finally painted with red insulating paint. Terminals are built with extruded aluminum flat bars welded to the conductor along its entire width thus ensuring

    Get Price
  • Internship report - SlideShare

    2016-11-15 · The terms winding and coil are used interchangeably in this discussion. Copper and aluminum are the primary materials used as conductors in power-transformer windings. While aluminum is lighter and generally less expensive than copper, a larger cross section of aluminum conductor must be used to carry a current with similar performance as copper.

    Get Price
  • Arab Tech Group

    The windings are generally made up of copper. However, Aluminum windings can also be offered. All the standard designs have been proven by type testing including impulse, temperature rise, sound level and short circuit tests. Utes's substation distribution transformers share the following features:

    Get Price
  • Three Phase Transfarmer - Three Phase Transformer ...

    Dyn11. Winding Material. Copper Aluminium. Primary Voltage. 11, 22, 33 KV. Secondary Voltage. 433/415/400 V or as per customer specifications and requirement. Duty, type. Continuous duty Outdoor/Indoor, Conventional or hermetically sealed. Mounting. Pole or Ground Mounted. No. Of Phases. 3 Phase. Class of insulation. Class A. Frequency. 50 Hz ...

    Get Price
  • 51-SDMS-04 SPECIFICATIONS FOR DISTRIBUTION

    2016-5-30 · mm² copper or 70 mm² aluminum with heat/cold/pre-mold termination. The box shall have single-gasket, removable, bolted cover. Its bottom plate shall be in two halves with cable entry steel knockouts suitable for the aforementioned cables. Loose rubber bushings shall be provided inside of this box for the knockouts.

    Get Price
  • SCB-800kVA 10kV Dry Type Transformer

    2021-8-18 · Cooling mode: AN/AF: Winding material (HV) Copper/Copper: Optional Windings : Aluminum/Aluminum: Degree of protection: IP00: HV tapping +/-2*2.5%: Insulation material : Cast resin (HV) Pre-impregnated (LV) Insulation level: Primary: 28kV AC Secondary: 3kV AC: BIL: 75kV for primary circuit: Type of installation: Indoor: Maximum attitude <1000m ...

    Get Price
  • Classes 7200, 7300, 7400 - Steven Engineering

    2004-10-26 · 225–10,000 kVA (fan cooling allows ... Basic impulse level of the primary winding shall be [_____kV] [as specified in ANSI C57.12.00 for comparable kV class]. G. The transformer shall be of sealed-tank construction or sufficient strength to withstand ... H. Coils shall be wound with [copper] [aluminum] conductors. I. Core and coil assembly ...

    Get Price
  • Medium voltage products Technical guide The MV/LV ...

    2018-7-15 · controlgear - Part 210: Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV – CEI 99-4: Customer/End user guide to creating MV/LV electrical substations – CEI EN 61936-1: CEI classification: 99-2, Power

    Get Price
  • Cast Resin Transformers

    OTDS manufactures 3 phase cast resin transformers up to 15mva and dry type up to 150kva. Our voltage range is up to 36kv for cast resin units and 3kV on dry type transformers. Our three-phase transformers of cast resin type, class F insulation system with natural (AN) cooling are designed for indoor installation.

    Get Price
  • 3 Speed Evaporative Cooler Motor 450V 10μF Capacitor ...

    2021-9-10 · Winding: 100% pure copper. Product features: 1. Single phase motor with steel housing, designed for cooling system, evaporative cooler etc, suit for hot weather environments. ... 375W 1/2 HP Air Cooler Motor Electric AC Air Conditioning System. Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Spe...

    Get Price
  • english - EL.PI. CAST-RESIN

    2013-9-18 · LV windings are made with an aluminum conductor strip featuring the same height as the winding and a class F insulation strip, then they are vacuum impregnated in epoxy resin and finally painted with red insulating paint. Terminals are built with extruded aluminum flat bars welded to the conductor along its entire width thus ensuring

    Get Price
  • Internship report - SlideShare

    2016-11-15 · The terms winding and coil are used interchangeably in this discussion. Copper and aluminum are the primary materials used as conductors in power-transformer windings. While aluminum is lighter and generally less expensive than copper, a larger cross section of aluminum conductor must be used to carry a current with similar performance as copper.

    Get Price
  • Arab Tech Group

    The windings are generally made up of copper. However, Aluminum windings can also be offered. All the standard designs have been proven by type testing including impulse, temperature rise, sound level and short circuit tests. Utes's substation distribution transformers share the following features:

    Get Price
  • Three Phase Transfarmer - Three Phase Transformer ...

    Dyn11. Winding Material. Copper Aluminium. Primary Voltage. 11, 22, 33 KV. Secondary Voltage. 433/415/400 V or as per customer specifications and requirement. Duty, type. Continuous duty Outdoor/Indoor, Conventional or hermetically sealed. Mounting. Pole or Ground Mounted. No. Of Phases. 3 Phase. Class of insulation. Class A. Frequency. 50 Hz ...

    Get Price
  • 51-SDMS-04 SPECIFICATIONS FOR DISTRIBUTION

    2016-5-30 · mm² copper or 70 mm² aluminum with heat/cold/pre-mold termination. The box shall have single-gasket, removable, bolted cover. Its bottom plate shall be in two halves with cable entry steel knockouts suitable for the aforementioned cables. Loose rubber bushings shall be provided inside of this box for the knockouts.

    Get Price
  • SCB-800kVA 10kV Dry Type Transformer

    2021-8-18 · Cooling mode: AN/AF: Winding material (HV) Copper/Copper: Optional Windings : Aluminum/Aluminum: Degree of protection: IP00: HV tapping +/-2*2.5%: Insulation material : Cast resin (HV) Pre-impregnated (LV) Insulation level: Primary: 28kV AC Secondary: 3kV AC: BIL: 75kV for primary circuit: Type of installation: Indoor: Maximum attitude <1000m ...

    Get Price
  • Classes 7200, 7300, 7400 - Steven Engineering

    2004-10-26 · 225–10,000 kVA (fan cooling allows ... Basic impulse level of the primary winding shall be [_____kV] [as specified in ANSI C57.12.00 for comparable kV class]. G. The transformer shall be of sealed-tank construction or sufficient strength to withstand ... H. Coils shall be wound with [copper] [aluminum] conductors. I. Core and coil assembly ...

    Get Price
  • Medium voltage products Technical guide The MV/LV ...

    2018-7-15 · controlgear - Part 210: Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV – CEI 99-4: Customer/End user guide to creating MV/LV electrical substations – CEI EN 61936-1: CEI classification: 99-2, Power

    Get Price
  • Cast Resin Transformers

    OTDS manufactures 3 phase cast resin transformers up to 15mva and dry type up to 150kva. Our voltage range is up to 36kv for cast resin units and 3kV on dry type transformers. Our three-phase transformers of cast resin type, class F insulation system with natural (AN) cooling are designed for indoor installation.

    Get Price
  • 3 Speed Evaporative Cooler Motor 450V 10μF Capacitor ...

    2021-9-10 · Winding: 100% pure copper. Product features: 1. Single phase motor with steel housing, designed for cooling system, evaporative cooler etc, suit for hot weather environments. ... 375W 1/2 HP Air Cooler Motor Electric AC Air Conditioning System. Air Cooler Cooling Fan Electric Motor Customized Aluminum Sell 50Hz 2 Spe...

    Get Price
  • english - EL.PI. CAST-RESIN

    2013-9-18 · LV windings are made with an aluminum conductor strip featuring the same height as the winding and a class F insulation strip, then they are vacuum impregnated in epoxy resin and finally painted with red insulating paint. Terminals are built with extruded aluminum flat bars welded to the conductor along its entire width thus ensuring

    Get Price
  • Internship report - SlideShare

    2016-11-15 · The terms winding and coil are used interchangeably in this discussion. Copper and aluminum are the primary materials used as conductors in power-transformer windings. While aluminum is lighter and generally less expensive than copper, a larger cross section of aluminum conductor must be used to carry a current with similar performance as copper.

    Get Price
Contact Us